SMX-RNS20 Firmware Changelog
- Log export to a syslog / SIEM server on your own network (System → Log Export (Syslog)) — RFC 5424 over UDP, TCP or TLS, off by default. See Sending logs to a syslog / SIEM server
- Audit record on the device: logins, lockouts, password and settings changes, firewall changes, configuration export/import, factory reset, firmware update actions, reboots and time changes, one
smx-rns-auditline each - The firewall now tells the remote-access tunnel and the machine LAN apart by the port a packet arrives on, not by its address. Two things follow: the device status over Modbus TCP (port 5020) is no longer readable through the tunnel — read it on the management interface; and the USB redirector is reachable only through the tunnel, no longer from the machine LAN
- Port forwarding: the device’s own ports (3000, 3200, 3201, 5020, 8080, 502, 33064) are reserved. A forwarding rule onto one of them is dropped — recreate it on another port
- Configuration backups are protected by a passphrase you choose when exporting (8 characters or more). The device keeps neither the passphrase nor a copy: a backup whose passphrase is lost cannot be restored. A backup restores on any SMX-RNS20 that is given the passphrase, so a replacement unit can be brought up from the old one’s file
- Backups taken with firmware 3.x cannot be restored on 4.0 (they were not passphrase-protected). Note the settings before updating a 3.x device; the in-place update itself keeps them
- A USB stick plugged into the device no longer loads settings. Restore a backup through the management interface only
- IPv6 is no longer enabled on the device; every service and every firewall rule is IPv4
- Repeated failed logins on the management interface are refused with an increasing wait (5 seconds, doubling up to 5 minutes), per source address; SX-IO’s login applies the same rule. Each refusal is in the audit record
- Local user accounts on the management interface (Settings → Users): the administrator creates a named account per person and ticks the areas it may change (Network, System, Backup (export), SX-IO); restoring a backup is the administrator’s alone; everyone reads every setting; the audit record names the person. A temporary password must be changed at first login
- A login notice: the administrator sets a text (up to 500 characters) that is shown before login on the management interface, at SSH connection and on the SX-IO login page
- Changing a password requires the current one, and ends every other session signed in with that account
- The administrator sets the minimum password length, on the management interface (Settings → Password policy) and on SX-IO (Users page): 6 to 64 characters, default 8; it applies whenever a password is set or changed and travels with a backup
- A 4.0 device no longer acts as a DNS server for devices on its LAN. If a PLC, HMI or PC on the LAN was configured by hand to use the SMX-RNS’s LAN address as its DNS server, point it at the site’s DNS server or gateway instead. Hotspot clients are not affected
- SMX-RNS20 4.0 requires SX-Client 5.1.0. SX-Client 5.1.0 is released first; only then does a device take 4.0. On a 4.0 device the portal refuses a connection from an older client and names the version to install. A client older than 5.1.0 with a 3.x device is unaffected
- With an older client, the device’s own services in SX-Client fail on a 4.0 device — resetting the device’s password, the network scan, the USB list and sharing a USB device. Update SX-Client to 5.1.0 first
- SX-IO has no factory password any more: switching SX-IO on asks for its admin password
- Remote access can be tied to the device’s digital input (Advanced → Remote access, off by default; HW R03, R03S and R11 only): with the option on, remote access is allowed while 24 V is on the input (key switch closed) and blocked otherwise — an open session is ended within about a second, the portal shows the device as “Blocked by digital input”. A broken wire counts as blocked, but a fault reading the input does not block — an input the device cannot read leaves remote access allowed, with the reason in the log. The device’s LAN, Modbus and management interface are not affected, and Simplinx’s service access is not gated by it. See Restricting remote access with the digital input
- The device’s hostname is now
<product>-<serial number>(for examplesmx-rns-PRDX0-00ABC), so its lines are attributable on your syslog server; a device without a certificate is stillsmx-rns - Secure boot on new-production HW R03S units: the device starts only firmware signed by Simplinx, checked at every start. Its compute module is bound to Simplinx’s key at the factory and cannot be swapped for one running unsigned software — a replacement module must come from Simplinx. Earlier hardware versions (HW R02, R03, R11) are not affected
- The system partition is read-only: the device’s settings live on their own partition, and nothing can change the system itself except a signed firmware update
- A restart on HW R11 units is quick again: from the management interface or at the end of a firmware update, such a device used to take about four minutes to come back, with its LEDs dark for most of that. Other hardware versions were never affected
V3.5.0
Section titled “V3.5.0”- Network Speed Measurement and Optimal P2P Path Selection
- Sharing Internet Over Wireless
- Wireless Network Scan
- Port Forward
- SX-IO — Serial Port
- SX-IO — Modbus RTU
- SX-IO — SQL Connection
- SX-IO — Multi Dashboard
- Stability improvements
- Many new minor features & bug fixes
V3.4.0
Section titled “V3.4.0”- Update Monitor
- Export/Import
- Stability improvements
- Many new minor features & bug fixes
V3.3.0
Section titled “V3.3.0”- Stability improvements
- Many new minor features & bug fixes
V3.2.0
Section titled “V3.2.0”- Modbus TCP support
- Stability improvements
- Many new minor features & bug fixes
V3.1.0
Section titled “V3.1.0”- WLAN Bridge Mode
- Stability improvements
- Many new minor features & bug fixes
V3.0.0
Section titled “V3.0.0”- Operating System update
- Web VNC support
- Sub Device Connection support
- Stability & connection speed improvements
- Remote IO — Omron FINS driver
- Remote IO — Modbus TCP improvements
- Remote IO — Dashboard new extensions
- Many new minor features & bug fixes
V2.12.0
Section titled “V2.12.0”- Remote IO communication improvements
- Remote IO SMS connection
V2.11.0
Section titled “V2.11.0”- Remote IO — Modbus TCP
- Remote IO — Siemens S7
- Remote IO — OPC UA
V2.10.0
Section titled “V2.10.0”- LAN → WAN pass-through option
V2.9.0
Section titled “V2.9.0”- USB support (final release)
- Device location info
- Connection speed enhancements
V2.8.0
Section titled “V2.8.0”- USB support Beta 2
V2.7.0
Section titled “V2.7.0”- USB support Beta
V2.6.0
Section titled “V2.6.0”- Serial port support
V2.5.0
Section titled “V2.5.0”- WAN Bridge Mode
V2.4.0
Section titled “V2.4.0”- Bug fixes
V2.3.0
Section titled “V2.3.0”- Bug fixes
- Bridge Mode
V2.2.0
Section titled “V2.2.0”- Bug fixes
- New P2P Mode
V2.1.0
Section titled “V2.1.0”- Initial firmware